SD BIOSENSOR

[block_title title=”SD BIOSENSOR”][/block_title]
[media image=”1084″]

Test Name: STANDARD M nCoV Real-Time Detection kit

Test Type:  RT/PCR  LAB TEST

Korea EUA Approved 

STANDARD M nCoV Real-Time Detection kit is used for rapid identification and detection of novel coronavirus (2019-nCoV) nucleic acids in human nasopharyngeal swabs and throat swab samples.

  • One tube reaction for identification and detection of 2019-nCoV
  • One-step Real-Time RT-PCR
  • Provide all reagents required for PCR
  • Designed according to “WHO interim guidance for laboratory testing for 2019 novel coronavirus (2019-nCoV) in humans”
  • nCoV primers/probes ORF1ab (RdRp) gene, E gene
  • Provide Internal controls
[services_large title=”Specifications” icon=”steadysets-icon-book2″]

Test Time: Within 90 minutes

Specimen: Nasopharyngeal swab, Oropharyngeal swab, Sputum

Storage temperature: -25~ -15℃/-13~ 5℉

Applicable Machine: CFX96. ABI7500

[/services_large]

[services_large title=”Applications” icon=”steadysets-icon-syringe”]

  • Nasopharyngeal Swab
  • Oropharyngeal Swab
  • Sputum

[/services_large]

[services_large title=”Compatibility” icon=”steadysets-icon-settings”]

  • LightCycler 480 (Roche)
  • Applied Biosystems 7500 Real-Time PCR Instrument System (Thermo Fisher Scientific)
  • CFX96 DX System (Bio-Rad)

[/services_large]

[services_large title=”Benefits” icon=”steadysets-icon-star”][/services_large]

Fast & Easy

  • One Tube Reaction for identification and Detection of 2019-nCoV
  • One-step Real-Time RT-PCR
  • Provide all reagents required for PCR

High Sensitivity & Specificity

  • Designed according to “WHO interim guidance for laboratory testing for 2019 novel coronavirus (2019-nCoV) in humans”
  • nCoV primers/probes ORF1ab (RdRp) gene, E gene
  • Provide Internal controls
[services_large title=”Key Components” icon=”moon-key-3″]

Components Quantity Test Dosage in each reaction
1 2019-nCoV Reaction Solution 750ul / vial x 2 14ul
2 RTase Mix 630ul / vial x 1 6ul
3 2019-nCoV Positive control 600ul / vial x 1
4 Negative control 600ul / vial x 1
5 Internal Control A 525ul / vial x 1 5ul (Add with Specimen)
0.5ul (Amplification directly)
6 ROX 55ul / vial x 1 0.5ul (for Applied Biosystems 7500)

[/services_large]

[services_large title=”Cycle Conditions” icon=”steadysets-icon-reload”]

Components Quantity Test Dosage in each reaction
1 2019-nCoV Reaction Solution 750ul / vial x 2 14ul
2 RTase Mix 630ul / vial x 1 6ul
3 2019-nCoV Positive control 600ul / vial x 1
4 Negative control 600ul / vial x 1
5 Internal Control A 525ul / vial x 1 5ul (Add with Specimen)
0.5ul (Amplification directly)
6 ROX 55ul / vial x 1 0.5ul (for Applied Biosystems 7500)